Number of Pages: 50

File Size: 1617 KB

File Type: MS Word & PDF

Chapters: 1 - 5

5,000.00

ABSTRACT

As the demand of electricity from an already congested network increases, ensuring voltage stability across the network becomes challenging. One approach in ensuring system stability is to attain system redundancy but their economic and ecological limitations to this. A more cost effective means would involve the use of existing network component and incorporate less expensive scheme and policies to maintain reliable system operation. Flexible alternating Current Transmission System (FACTS) such as the Unified Power Flow Controller (UPFC) are devices incorporated to achieve improvement in overall system performance such s increasing transmission line flows, minimizing losses, and improving voltage profile across the network buses.

Table Of Contents

Approval Page                                                                                      Vi

Certification                                                                                                    Vii

Dedication                                                                                             Viii

Acknowledgement                                                                                             Ix

Abstract                                                                                                  X

Table of Contents                                                                                   Xi

List of Figures                                                                                         Xiii

List of Tables                                                                                            Xiv

Introduction                                                                                                         1

1.1. Background                                                                                        1

1.2. Statement of Problem                                                                          2

1.3. Aim and Objective                                                                               2

1.4. Project Outline                                                                                     3

CHAPTER TWO                                                                                        4

LITERATURE REVIEW

2.1.1 Concept of FACT                                                                                      4

2.1.1. Voltage Stability                                                                                5

2.1.2. Voltage Collapse                                                                              5

7

2.1. CONVENTIONAL METHODS OF REACTIVE POWER

COMPENSATION                                                                                     7

2.1.1. Shunt Reactors                                                                                 7

2.1.2. Shunt Capacitors                                                                              8

2.1.3. Synchronous Condensers                                                                           9

2.1.4. Load shedding                                                                                  10

2.1.5. Tap Changing of Transformers                                                                  10

2.2. FLEXIBLE ALTERNATING CURRENT TRANSMISSION SYSTEMS (FACTS)                                                                                                        11

2.2.1. Static Synchronous Compensator (STATCOM)                              12

2.2.2. Thyristor-Switched Series Capacitor (TSSC)                                            13

2.2.3. Static Synchronous Series Compensator (SSSC)                                       14

2.2.4. Thyristor-Controlled Series Capacitor (TCSC)                                16

2.2.5. Unified Power Flow Controller (UPFC)                                           17

CHAPTER THREE                                                                                    20

METHODOLOGY                                                                                     20

3.1. LOCATION OF UPLC                                                                        20

3.2. Newton Raphson Load Flow Method                                                 21

3.2.1. Formation of the Y-bus                                                                              24

3.2.2. Forming the Jacobian matrix                                                            25

3.3. Incorporating the UPLC in Newton Raphson Load Flow                             26

CHAPTER FOUR                                                                                                30

SIMULATION AND RESULTS ANALYSIS                                            30

CHAPTER FIVE                                                                                        35

CONCLUSION AND RECOMMENDATIONS                                         35

APPENDIX A                                                                                            38

References                                                                                                  43

LIST OF FIGURES

Figure2. 1 A reactor located at 330/132KV transmission station in

Alaoji, Aba, Abia State                                                                              8

Figure2. 2 A typical capacitor bank                                                           9

Figure2. 3 A static synchronous compensator                                           13

Figure2. 4.(a) circuit diagram of a TSSC, (b) course of capacitor voltage for

the basic element in a TSSC                                                                      13

Figure2. 5:: (a) A two machine system with a series capacitor compensated line, (b) its associated phasor diagram                                                                15

Figure2. 6:Thyristor-Controlled Series Capacitor (TCSC)                                   17

Figure2. 7: Concept of the UPFC in a two-machine power system            18

Figure2. 8: Implementation of UPLC                                                                   19

Figure3. 1: One line diagram of the power system model                                     20

Figure3. 2: A two bus system for illustrating Newton Raphson Power flows      24

Figure3. 3:Unified power flow controller equivalent circuit                       26

Figure 4. 1:voltages of the buses without the UPFC between buses 3 and 4        31

Figure 4. 2: voltages of the buses with the UPFC between buses 3 and 4  32

LIST OF TABLES

Table 4. 1:Bus voltages without the UPFC                                                30

Table 4. 2.Line Flows and Losses without UPFC                                                31

Table 4. 3. Bus voltages with UPFC                                                          32

Table 4. 4. Line Flows and Losses with UPFC                                           33

Table 4. 5: voltages of the buses with and without the UPFC between buses

3 and 4                                                                                                      34

INTRODUCTION

1.1. BACKGROUND

The control of voltage and power flows is a major issue in power system operation. This is because, due to the topological differences between distribution and transmission systems, different strategies have evolved.

This project contains contributions for power flows control and voltage stability schemes for distribution and transmission systems. A particular interest is taken to the development of control schemes to avoid so-called voltage collapse, which can result in widespread outages. In order to achieve efficient and reliable operation of power system, the control of voltage and reactive power should satisfy the following objectives:

  • Voltages at all terminals of all equipment in the system are within acceptable limits
  • System stability is enhanced to maximize utilization of the transmission system
  • The reactive power flow is minimized so as to reduce RI2 and XI2

This ensures that the transmission system operates mainly for active power. Since the power system supplies power to a vast number of loads and is feeding from many generating units, there is a problem of maintaining voltages within required limits. As load varies, the reactive power requirements of the transmission system vary. Since there is no cost free means of conveying reactive power over long distances, voltage control has to be effected by using special devices located through the system which possess difficulties in keeping sufficient levels of voltage in the power system network.

In recent decades, there has been significant progress in terms of equipment designed to improve the stability of voltage in power systems. This is mainly due to the development of power supply systems in the world, which requires seeking better ways of adjusting and controlling power flows and voltage levels

The proper selection and coordination of equipment for controlling reactive power and voltage stability are among the major challenges of power system engineering. These challenges necessitated the evolution of certain to achieve control or compensation of reactive power. In order to cover the additional demand for reactive power and retain the ability to control voltage stability acceptable range, various sources of reactive power, particularly of the FACTS family has been employed.

 

1.2. Statement of Problem

The characteristics of a given power system evolve with time, as load grows and generation is added. If the transmission facilities are not upgraded sufficiently the power system becomes vulnerable to steady-state and transient stability problems, as stability margins become narrower, posing a limit on the ability of these lines to transmit power. In principle, limitations on power transfer can always be relieved by the addition of new transmission and generation facilities. Conversely, these are not easy to come by, coupled with the high cost of executing such projects. Alternatively, UPFC can enable the same objectives to be met with no major alterations to system layout. How UPFC can be used to attain a great degree of power flow and voltage profile controllability in power system network is the challenge of this project.

 

1.3. Aim and Objective

1.3.1 Aim

To implement unified power flow controller (UPFC) for improvement of voltage stability in a congested electric network

 1.3.2 Objective

To develop mathematical models for transmission systems and UPFC, which can to be blended together, coded, and used extensively.

To illustrate the controllable features of  UPFC in active and reactive power flows in a transmission line.

To maintain the nodal voltage magnitudes in a power system in the limit for system security

 

1.4. Project Outline

Chapter 1 introduces the work carried out in this project and lists its objectives and

limitations.

Chapter 2 focuses on the literature review.

Chapter 3 presents the methodology adopted in completing the project, the modeling equations and mathematical solutions backing up the work.

Chapter 4 presents the simulation  work done in MATLAB and discuss the results.

Chapter 5 presents the conclusion, recommendations and future areas of research.

DOWNLOAD THE FULL WORK

DISCLAIMER: All project works, files and documents posted on this website, UniProjectTopics.com are the property/copyright of their respective owners. They are for research reference/guidance purposes only and some of the works may be crowd-sourced. Please don’t submit someone’s work as your own to avoid plagiarism and its consequences. Use it as a reference/citation/guidance purpose only and not copy the work word for word (verbatim). The paper should be used as a guide or framework for your own paper. The contents of this paper should be able to help you in generating new ideas and thoughts for your own study. UniProjectTopics.com is a repository of research works where works are uploaded for research guidance. Our aim of providing this work is to help you eradicate the stress of going from one school library to another in search of research materials. This is a legal service because all tertiary institutions permit their students to read previous works, projects, books, articles, journals or papers while developing their own works. This is where the need for literature review comes in. “What a good artist understands is that nothing comes from nowhere. All creative work builds on what came before. Nothing is completely original.” - Austin Kleon. The paid subscription on UniProjectTopics.com is a means by which the website is maintained to support Open Education. If you see your work posted here by any means, and you want it to be removed/credited, please contact us with the web address link to the work. We will reply to and honour every request. Please notice it may take up to 24 – 48 hours to process your request.